 P Series Diesel Fuel Conditioning Module

 

The patented P Series diesel fuel conditioning module (for vacuum side applications only) was developed for application in any diesel engine fuel injection system.  P Series assemblies are available in three sizes and all feature 3/8” NPT fuel ports. This innovative and modular fuel filter / water separator incorporates low-pressure fuel system components into a single package.
 

 

 

 

 

P3

P4

P5

Basic Models

P3

P4

P5

Maximum Flow Rate

30 gph / 114 lph

40 gph / 170 lph

50 gph / 227 lph

Clean Pressure Drop

0.4 psi / 2.8 kPa

0.5 psi / 3.4 kPa

0.8 psi / 5.5 kPa

Maximum Pump Output (at 14.4 volts)

40 gph / 151 lph

40 gph / 151 lph

40 gph / 151 lph

Standard Fuel Port Size (SAE J476)

3/8” - 18 NPT

3/8” - 18 NPT

3/8” - 18 NPT

Total Number of Ports Available:
Fuel Inlets
Fuel Outlets

2
1
1

2
1
1

2
1
1

Replacement Elements:
02 micron
10 micron
30 micron


R58060-02
R58060-10
R58060-30


R58095-02
R58095-10
R58095-30


R58039-02
R58039-10
R58039-30

Minimum Service Clearance

2.5” (28 mm)

2.5” (28 mm)

2.5” (28 mm)

Height

7.7” (196 mm)

9.0” (229 mm)

11.5” (292 mm)

Depth

5.2” (132 mm)

5.2” (132 mm)

5.2” (132 mm)

Width

4.8” (122 mm)

4.8” (122 mm)

4.8” (122 mm)

Weight (dry)

3.4 lb (1.5 kg)

3.8 lb (1.7 kg)

4.2 lb (1.9 kg)

Maximum Pump Output Pressure

10 psi (69 kPa)

10 psi (69 kPa)

10 psi (69 kPa)

Features: 1
Water Sensor
Heater
Pressure Regulator (10 psi)


Standard
Standard
Standard


Standard
Standard
Standard


Standard
Standard
Standard

Operating Temperature

-40 to +255F / -40 to +121C

Vacuum installations are recommended.
Not for use with gasoline applications.

 


How to Order - The example below illustrates how part numbers are constructed.

P4

2

10

N

H

Specify
‘P3’ for 30 gph,
‘P4’ for 40 gph
or ‘P5’ for 50 gph

‘2’ must be in the part number. (It specifies a 12 vdc pump)

Specify micron rating of element:
‘02’, ‘10’, or ‘30’

‘N’ must be in the part number. (It specifies standard 3/8” NPT ports)

‘H’ must be in the part number. (It specifies a 12 vdc, 150 watt heater)